Output type: NAMUR Rated operating distance: 0.8 mm Installation: flush Assured operating distance: 0 … 0.65 mm
Operating voltage: 5 … 25 V Switching frequency: 0 … 5000 Hz Measuring plate not detected: ≥ 3 mA at nominal voltage Measuring plate detected: ≤ 1 mA at nominal voltage
Ambient temperature: -25 … 100 °C (-13 … 212 °F) Degree of protection: IP67